PAECT ferry complex (mobile automated power station of container type) is intended for ferrying of EKG-5a, EKG-8I, EKG-10, EKG-12K, EKG-15 and their modifications, as well as drilling machines in the absence of 6kV cable line.
PAECT ferry complex (mobile automated power station of container type) is intended for ferrying of EKG-5a, EKG-8I, EKG-10, EKG-12K, EKG-15 and their modifications, as well as drilling machines in the absence of 6kV cable line.
Typical set of the ferry complex:
- Low-voltage switchgear (LVS) of KSR-500/2400 type,
- Diesel generator set (DGU) of 250 or 400 kW,
- container,
- chassis - a cross-country vehicle, or a car trailer.
The names of ferry complexes for ordering are given in the table.
Name | Main Features |
---|---|
ED400-T400-1RAM1 | Based on KAMAZ-43118. DGU type AD400-T400-1R with a capacity of 400 kW. DGU based on YaMZ-8503.10-01 engine. |
ED250-T400-1RAM1 | Based on KAMAZ-43118. DGU type AD250-T400-1R with a capacity of 250 kW. DGU based on YaMZ-7514.10-03 engine. |
ED400-T400-1RKM1 | Based on a car trailer. DGU type AD400-T400-1R with a capacity of 400 kW. DGU based on YaMZ-8503.10-01 engine. |
ED250-T400-1RKM1 | Based on a car trailer. DGU type AD250-T400-1R with a capacity of 250 kW. DGU based on YaMZ-7514.10-03 engine. |
By special agreement the use of MAZ truck is possible; also it is possible to use Volvo Penta engine as a part of DGU.
Transporter complexes with capacity of the 250kW ДГУ are designed for operation with excavators EKG-5a, EKG-8I, EKG-10, EKG-12K and drilling rigs. At capacity DGU 400kW the possibility of ferrying excavator EKG-15 is added.
During the hauling of the excavator the ferry complex on the basis of the car trailer has to be transported after the hauled excavator with the help of a hauling truck.
The ferrying complex is equipped with:
- cable drum with electric drive for cable storage. In the transport position, the cable drum is closed with a protective cover,
- covers to protect the ventilation holes in the container. The covers are fixed in two positions - open (when hauling the excavator) and closed (when transporting the hauling station),
- secret key locks on container doors,
- retractable rods for securing cables during hauling,
- floodlight to illuminate the route of the crossing,
- retractable ladders for access to the container (separately in the section of the low-voltage switchgear, separately in the section of the diesel generator),
- external illumination over the container doors,
- filler neck for the DGU fuel tank, located on the outer side wall of the container,
- ladder to access the filler neck of the DGU fuel tank,
- removable side walls of the compartments for low-voltage switchgear and diesel generator sets to facilitate repair work at the transfer station,
- fire extinguishing system,
- the system of internal lighting of the container,
- cable connection panel, located on the outer side wall of the container. In the transport position, the panel is closed with a protective cover,
- the system of starting preheating of the DGU engine,
- fitting fastening of the container to the mobile platform. If necessary, the container can be easily removed and installed on another platform.