Low-voltage complete control unit ESh-11/70 for draglines excavators
The ESh-11/70 low-voltage complete unit is designed for controlling draglines.
Single-bucket backhoe draglines are the main machines used in coal and ore mines as extraction and stripping machines and as the most satisfactory machines to work in the most severe mining, geological and climatic conditions.
Low-voltage switchgears (LVS) ESh-11/70 are designed for:
- providing regulated DC voltage for excitation circuits of generators using "thyristor converter - generator - motor" (TV-G-D) system with a digital double-circuit parameter slave control system and a digital adaptive intensity setter at the system input;
- providing stabilized current supply to excitation circuits of main electric drives motors;
- preliminary acceleration of four-machine converter unit up to sub-synchronous speed by "thyristor converter-motor" system (TP-D);
- excitation current supply to the synchronous motor (PM) as a function of time, with subsequent automatic regulation of excitation, depending on the value of the active component of the PM stator current;
- control of electric drives of auxiliary mechanisms;
- formation of required static and dynamic characteristics of main electric drives;
- supplying of light signals to driver's control panels about energized state of electric drives, as well as light and sound signal in case of emergency state of electric equipment;
- control of relay-contactor circuit;
- diagnostics and automatic control of thyristor converters with microprocessor control.
They provide:
- energy saving due to original circuit solutions;
- convenience of maintenance, effective self-diagnostics, high speed and excellent controllability of excavator mechanisms.
Composition of LVS
№ | Name | Quantity | Dimensions | Mass, kg | ||
---|---|---|---|---|---|---|
Width, mm | Depth, mm | Height, mm | ||||
1 | Exciter cabinet | 1 | 1400 | 550 | 1900 | 550 |
2 | Static Transducer Cabinet | 1 | 1000 | 550 | 1900 | 400 |
3 | Auxiliary Drive Cabinet | 1 | 1300 | 550 | 1900 | 390 |
4 | Relay-contactor cabinet | 1 | 1100 | 550 | 1900 | 500 |
5 | Кресло-пульт (К-П) | 1 | 700 | 370 | 940 | 60 |
6 | Remote control chair | 1 | 400 | 210 | 900 | 40 |
7 | Grease control cabinet | 1 | 700 | 360 | 800 | 50 |
8 | Control cabinet for liquid grease heating | 1 | 680 | 187 | 600 | 35 |
9 | PTEM Setting Panel* | 1 | 100 | 50 | 180 | 0,37 |
10 | Stand for PTEM adjustment* | 1 | 110 | 253 | 346 | 7 |
11 | Stand for TK adjustment* | 1 | 220 | 170 | 120 | 2,5 |
* – after-sales service.
Low-voltage switchgear and controlgear assemblies are designed as four main cabinets. All cabinets are one-sided service, relay-contactor cabinet (RCC) is two-sided service. On the front side the cabinets have doors equipped with special locks. On the roof of the cabinets are transportation eyebolts. At installation on site the bolts can be removed, and the free holes are used for additional attachment of cabinets to the walls of the excavator body. Inside the cabinets there is control and protection equipment, the composition and description of which is given in the relevant manuals for the cabinets. Measuring instruments and light signaling lamps are installed on the cabinet doors and on the swing panel. In the bottom part of cabinets there are terminal blocks for connection of external installation cables. Cables are led through the open openings of the bottom frames. Grounding of cabinets is realized through external and internal grounding clamps, located in the right or left bottom part of cabinets. Upon agreement with the customer, transformers are included in the package of low-voltage switchgear and controlgear assemblies.
№ | Parameter | Use in LVS | ||||
---|---|---|---|---|---|---|
Generator exciters | Engine exciters | SD exciters | Control circuits | Lighting | ||
1 | Transformer type | TSZM-16-74.OM5 | TSZM-16-74.OM5 | TSZM-16-074.OM5 | TSZI-2,5 | TSZM-25-74.OM5 |
2 | Rated power, kVA | 16 | 16 | 16 | 2,5 | 25 |
3 | Primary winding voltage, V | 380 | 380 | 380 | 380 | 380 |
4 | Secondary winding voltage, V | 220 | 220 | 36 | 72 | 220 |
5 | Rated secondary current, V | 70,5 | 40,8 | 245 | 19,3 | 70,5 |
6 | Winding connection diagram | Y/Y o | Y/Y | Y/Δ | Y/Δ | Y/Δ |
7 | Quantity, pcs | 3 | 1 | 1 | 1 | 1 |
8 | Mass, kg | 200 | 145 | 145 | 31 | 200 |
The following may be included in the scope of supply at the customer's request:
- Set of high-voltage and low-voltage cable products.
- High-voltage cubicle KRU-6R-U2 (installed on excavator platform).
- Switching unit KRU-6RPP-U1 (YaKNO).